Page 1 of 8
TO: Development Services Customers
SUBJECT: INFORMATION BULLETIN 526
Standard Plat Note Layout
DATE: Issued March 25, 2010 / Revised September 9, 2011 / August 2, 2013 /
August 1, 2014 / March 28, 2018 / May 9, 2018
CREATED BY: Land Development Division/Land Entitlements Section
Purpose:
As a customer service initiative, the Development Services Department (DSD) revised
Information Bulletin (IB) 526 Standard Plat Note Layout. This updated bulletin incorporates an
updated list of approved plat notes along with updated templates denoting plat layout. The
previous revision did not include the list of plat notes or the templates. The purpose of this IB is
to provide a standardized note and template format for plat preparation.
The Bexar County Clerk’s Recording Office requested the removal of their recordation block
found at the lower right hand corner of the plat to be left blank, due to their new Records
Management System Update generating recording labels. This request came after the IB was
finalized on March 28, 2018 resulting in this revision to update the plat layout to reflect the
changes.
Scope:
Through the plat note update process, DSD has coordinated with numerous authorizing
agencies to update the individual plat notes. These updates do not require an amendment to the
Unified Development Code (UDC) and were fully vetted through key stakeholders. An
updated list has been created (Exhibit “A”) depicting each of the approved plat notes. This
revised IB includes several templates (Exhibit “B”), designed for new plat submittals. The
template also includes the spacing height and length requirements for Bexar County
Commissioners Court signature block. For multiple page plats, the plat notes only need to be
shown on the last page; however, signature blocks, CPS Energy, and SAWS notes are required
on every page.
Summary:
This IB is for informational purposes only. For additional information regarding this IB, please
contact the Land Entitlements Section at (210) 207-0121.
Prepared by: Larry Odis, Senior Planner
Reviewed by: Melissa Ramirez, Assistant Director
Authorized by: Michael Shannon
, PE, CBO, Director
Page 2 of 8
Agency, Note Name,
and/or Origin
"Exhibit A"
Plat Note Text
1.
Common Area
Maintenance:
The maintenance of all private streets, open space, greenbelts,
parks, tree save areas, including Lot ___, Block ___, CB or NCB
___, drainage easements and easements of any other nature within
this subdivision shall be the responsibility of the Property Owners, or
the Property Owners' Association, or its successors or assigns and
not the responsibility of the City of San Antonio or Bexar County.
San Antonio (TCI) and Bexar County Floodplain Notes. Use Note
#2 and choose one of notes 3 - 5) if the property contains
floodplain. Use note #6 if the property does not contain
floodplain. Minor variations may be approved by TCI or Bexar
County.
2. Easements for
Floodplains
35-F124(C)
The drainage easements were delineated to contain the lesser of the
boundaries of the 1% annual chance (100-year) flood zone
established by the Federal Emergency Management Agency (FEMA)
in accordance with DFIRM Panel ____, dated ____ ; or the 1%
annual chance (100-year) ultimate development condition water
surface elevation; or the 4% annual chance (25-year) ultimate
development floodplain plus freeboard. Construction, improvements,
or structures within the drainage easements and floodplain are
prohibited without prior written approval from the Floodplain
Administrator of the City of San Antonio or Bexar County.
3. LOMRs with FEMA
Approval
35-F132
The 1% annual chance (100-Year) floodplain limits shown on this
plat were delineated based upon a Letter of Map Revision (LOMR)
Study prepared by _____ and approved by FEMA on _____ (Case
No. _____). Floodplain information is subject to change as a result of
future FEMA Map revisions and/or amendments.
4. CLOMRs with FEMA
Approval
35-F132
The 1% annual chance (100-year) floodplain limits shown on this plat
were delineated based upon a Conditional Letter of Map Revision
(CLOMR) Study prepared by _____ and approved by FEMA on
_____ (Case No. _____). Floodplain information is subject to change
as a result of future FEMA Map revisions and/or amendments.
5. CLOMRs Pending
FEMA Approval
Lots thru , Block , CB or NCB ___, lie within the FEMA 1%
annual chance (100-year) floodplain as depicted on the FEMA Flood
Insurance Rate Map of Bexar County, Texas, DFIRM panel numbers
48029c and 48029c , dated _ . A FEMA CLOMR
floodplain study has been prepared by and was approved
by the city of San Antonio and/or Bexar County. The floodplain study
(FEMA Case No. _____) is pending approval by FEMA. Floodplain
information is subject to change as a result of future FEMA Map
revisions and/or amendments.
Page 3 of 8
6. Floodplain
Verification
No portion of the FEMA 1% annual chance (100-year) floodplain
exists within this plat as verified by FEMA Map Panel: 48029C_____,
effective [date]. Floodplain information is subject to change as a
result of future FEMA Map revisions and/or amendments.
Additional Floodplain and Storm Water Notes 7 - 15 to be used
with the Floodplain Notes above if applicable:
7. County Finished
Floor Elevation –
Relative to Floodplain
F-142(a) & (b)(1)
Finished floor elevations for structures on lots containing floodplain
or adjacent to the floodplain shall be in compliance with the
floodplain regulation in effect at time of construction. Contact Bexar
County Public Works for more information.
8.
Residential Finished
Floor
Appendix H. 15.2
and Appendix H.
Appendix A.1.III.A.8
Residential finished floor elevations must be a minimum of eight (8)
inches above final adjacent grade. (This note is required on all
residential and OCL plats)
9. Residential Finished
Floor Elevation – City
Only. Required for lot
s
co
ntaining, adjacent to,
or abutting floodplain.
F125(a)(2) &
F142(a)(1)
Residential structures are not allowed within the City of San Antonio
ultimate development floodplain. Finished floor elevations for
residential structures shall be no less than one foot above the base
flood elevation of the regulatory floodplain (City of San Antonio
ultimate development floodplain). The lowest adjacent grade shall be
at or above the base flood elevation. Pre-construction elevation
certificates may be required prior to permit approval, and post-
construction elevation certificates may be required prior to
occupancy of residential buildings, as determined by the Floodplain
Administrator of the City of San Antonio.
10. Non-Residential
Finished Floor
Elevation – City Only.
Required for lots
containing, adjacent to,
or abutting floodplain.
F124(f)(17) & F142(b)
Finished floor elevations for non-residential structures shall be no
less than one foot above the base flood elevation of the regulatory
floodplain (City of San Antonio ultimate development floodplain).
The lowest adjacent grade shall be at or above the base flood
elevation. Flood-proofing may be allowed if elevating the structure is
not feasible, if approved by the Floodplain Administrator of the City of
San Antonio.
11.
Detention for
previously recorded
plat.
Storm water detention is required for this property and is accounted
for in an offsite detention pond located in Lot _____, Block ____, CB
or NCB ____, Subdivision Unit _____, recorded in Volume _____,
Page _____ (Plat # _____).
12.
Drainage Easement
Encroachments
Appendix H. Appendix
A.1.III.A.7
No structure, fences, walls or other obstructions that impede
drainage shall be placed within the limits of the drainage easements
shown on this plat. No landscaping or other type of modifications,
which alter the cross-sections of the drainage easements, as
approved, shall be allowed without the approval of the Director of TCI
or Director of Public Works. The City of San Antonio and Bexar
County shall have the right of ingress and egress over the grantor’s
adjacent property to remove any impeding obstructions placed within
the limits of said drainage easement and to make any modifications
or improvements within said drainage easements.
Page 4 of 8
13. TCI Detention &
Maintenance
Appendix H. 4.7.1
Storm water detention is required for property within the boundary of
this plat. Building permits shall be issued only in conjunction with
necessary storm water detention approved by the City of San
Antonio Floodplain Administrator. The property may be eligible to
post a fee in lieu of detention (FILO) if offsite drainage conditions
allow but only when approved by the City of San Antonio Floodplain
Administrator. Maintenance of on-site storm water detention shall be
the sole responsibility of the property owners and/or the property
owners’ association and its successors or assigns and is not the
responsibility of the City of San Antonio or Bexar County.
14.
LID - Voluntary
35-210(b)(4)F.
The property owner has elected to provide low impact development
(LID) and/or natural channel design (NCD) on Lot(s) ____, Block
___, NCB ____. Building permits for this property shall be issued
only in conjunction with necessary LID/NCD plans approved by the
City of San Antonio. The property may be eligible for credit and
offset incentives and/or fee incentives when approved by the City of
San Antonio. If the property owner elects not to provide LID and/or
NCDP, the incentives will not be granted and the property shall
conform to all applicable development standards of the City Code
Chapter 35, the Unified Development Code.
15. LID – Mandatory
Areas
35-673(c)(8)
Low impact development (LID) and/or natural channel design
(NCD) is required on lot(s) ___, block ___, NCB ____. Building
permits for this property shall be issued only in conjunction with
necessary LID/NCD plans approved by the City of San Antonio. The
property may be eligible for credit and offset incentives and/or fee
incentives when approved by the City of San Antonio.
16.
Clear Vision
Only required in OCL
35-506(d)(5)
Clear vision areas must be free of visual obstructions in accordance
with the American Association of State Highway and Transportation
Officials (AASHTO) Policy on Geometric Design of Highways and
Streets, or latest revision thereof.
17.
Vehicular Turn
Around
35-506(r)(2)
Owner shall provide for permanent vehicular turn around on Lot ___,
Block ___, CB or NCB ____, to prevent backing onto the roadway.
18.
Ingress/Egress
35-515(c)(4)
No structure, fences, walls, or other obstructions shall be placed
within the limits of the ingress/egress easement shown on this plat.
19.
Cross Access
35-506(r)(3)
Lot owner(s) shall provide shared common cross access for Lot(s)
___, Block ___, CB or NCB ____, in accordance with UDC 35-
506(r)(3).
20.Easement Expiring
to ROW
35-B121(12) and 35-
507(f)(1) and Appendix
H. Appendix A.1.III.A.6
Easement to expire upon incorporation into platted public street right-
of-way. (Note: to be used for public streets)
Easement to expire upon incorporation into platted private street.
(Note: to be used for private streets)
Page 5 of 8
21.
Private Street
Designation
Lot ____, Block ____, CB or NCB ____, is a private street and is
designated as an underground and at-grade infrastructure and
service facilities easement for gas, electric, street light, telephone
cable television, drainage, pedestrian, public water, wastewater, and
recycled water mains.
22.
CPS/SAWS/COSA
Utility
To be used on all plats
1.The City of San Antonio as part of its electric, gas, water, and
wastewater systems – City Public Service Board (CPS Energy) and
San Antonio Water System (SAWS) - is hereby dedicated easements
and rights-of-way for utility, transmission and distribution
infrastructure and service facilities in the areas designated on this
plat as "electric easement," "anchor easement," "service easement,"
"overhang easement," "utility easement," "gas easement,"
"transformer easement," “water easement,” “sanitary sewer
easement” and/or “recycled water easement” for the purpose of
installing, constructing, reconstructing, maintaining, removing,
inspecting, patrolling, and erecting utility infrastructure and service
facilities for the reasons described above. CPS Energy and SAWS
shall also have the right to relocate said infrastructure and service
facilities within easement and right-of-way areas, together with the
right of ingress and egress over grantor’s adjacent lands for the
purpose of accessing such infrastructure and service facilities and
the right to remove from said lands all trees or parts thereof, or other
obstructions which endanger or may interfere with the efficiency of
water, sewer, gas, and/or electric infrastructure and service facilities.
No buildings, structures, concrete slabs, or walls will be placed within
easement areas without an encroachment agreement with the
respective utility.
23.
CPS/SAWS/COSA
Utility
To be used on all plats
2. Any CPS Energy or SAWS monetary loss resulting from
modifications required of CPS Energy or SAWS infrastructure and
service facilities, located within said easements, due to grade
changes or ground elevation alterations shall be charged to the
person or persons deemed responsible for said grade changes or
ground elevation alterations.
24.
CPS/SAWS/COSA
Utility
To be used on all plats
3. This plat does not amend, alter, release or otherwise affect any
existing electric, gas, water, sewer, drainage, telephone, cable tv
easements or any other easements for utilities unless the changes to
such easements are described hereon.
25.CPS/SAWS/COSA
Utility
Add to notes above if
residential
4. Concrete driveway approaches are allowed within the five (5) and
ten (10) foot wide electric and gas easements when lots are served
only by underground electric and gas facilities.
26.CPS/SAWS/COSA
Utility
Add to notes above if
residential
5. Roof overhangs are allowed within the five (5) and ten (10) foot
wide electric and gas easements when only underground electric and
gas facilities are proposed or existing within those five (5) and ten
(10) foot wide easements.
Page 6 of 8
27.
TxDOT
1. For residential development directly adjacent to state right of way,
the property owner shall be responsible for adequate set-back and/or
sound abatement measures for future noise mitigation.
2. Maximum access points to State highway from this property will be
regulated as directed by “Access Management Manual”. This
property is eligible for a maximum total of ___ {existing} acce
ss
p
oint(s) along [name of TxDOT roadway], based on the overall
platted highway frontage of ___. [linear ft of highway frontage]
{access will be provided by one (1) access point on the adjacent
property outside the platted area along [name of TxDOT roadway].}
(Note: TxDOT may request verbiage in the curly brackets along with
additional language depending on the scenario.)
3. If sidewalks are required by appropriate city ordinance, a sidewal
k
p
ermit must be approved by TxDOT prior to construction within state
right-of-way. Locations of sidewalks within state right-of-way shall be
directed by TxDOT.
28.
San Antonio River
Authority
San Antonio River Authority (SARA) is hereby dedicated the
easements and rights-of-way for sanitary sewer collection and
treatment facilities in the areas designated on this plat as "sanitary
sewer easement" for the purpose of installing, constructing,
reconstructing, operating, maintaining, removing and inspecting
sanitary sewer pipelines and collections systems and all necessary
above-ground or below-ground appurtenances, together with the
right of ingress and egress over grantor's adjacent land, the right to
relocate said facilities within said easement and right-of-way and the
right to remove from said land all trees and vegetation or parts
thereof, or other obstructions which endanger or may interfere with
the function of said facilities. It is agreed and understood that no
buildings, structures, concrete slabs or walls will be placed within
easement areas without an encroachment agreement with SARA.
29.
SAWS Aquifer:
This subdivision is within the Edwards Aquifer Recharge Zone.
Development within this subdivision is subject to Chapter 34, Article
VI, Division 6 of the San Antonio City Code entitled "Aquifer
Recharge Zone and Watershed Protection," or the latest revisions
thereof. Any regulated activity must comply with all federal, state
and local regulations relating to development within the Edwards
Aquifer Recharge Zone.
30.
SAWS Impact Fee
Water and/or Wastewater Impact Fees were not paid at the time of
platting for this plat. All impact fees must be paid prior to water
meter set and/or wastewater service connection.
31.
SAWS Wastewater
EDU
35-B121(c)(18)
The number of wastewater equivalent dwelling units (EDU's) paid for
this subdivision plat are kept on file under the plat number at the San
Antonio Water System.
32.
SAWS Dedication
The owner dedicates the sanitary sewer and/or water mains to the
San Antonio Water System upon completion by the developer and
acceptance by the San Antonio Water System.
Page 7 of 8
33.
SAWS High Pressure
A portion of the tract is below the ground elevation of ____ feet
where the static pressure will normally exceed ___ psi. At all such
locations, the owner or builder shall install at each lot, on the
customer's side of the meter, an approved type pressure regulator in
conformance with the Plumbing Code of the City of San Antonio.
34.
Grey Forest Utility:
The City of Grey Forest, by and through its gas utility system, Grey
Forest Utilities is hereby dedicated easements and right-of-ways for
gas distribution infrastructure and service facilities in the areas
designated on this plat as "gas easement" for the purpose of
installing, constructing, reconstructing, maintaining, removing,
inspecting, and patrolling said infrastructure and service facilities
together with the right of ingress and egress over grantor's adjacent
land for the purpose of accessing its infrastructure and service
facilities. Grey Forest Utilities shall also have the right to relocate
said infrastructure and service facilities within easement and right-of-
way areas, and the right to remove from said area lands all trees or
parts thereof, or other obstructions which endanger or may interfere
with the efficiency of gas distribution infrastructure and service
facilities. No buildings, concrete slabs, or walls will be placed within
easement areas without an encroachment agreement with Grey
Forest Utilities.
35.
Residential Fire Flow
residential
development only IB-
187
The public water main system has been designed for a minimum fire
flow demand of ______ gpm at 25 psi residual pressure to meet the
City of San Antonio's fire flow requirements for the residential
development. The fire flow requirements for individual structures will
be reviewed prior to building permit approval in accordance with the
procedures set forth by the City of San Antonio Director of
Development Services and the San Antonio Fire Department Fire
Marshal.
36. FIRE:
Ingress and egress shall be provided between all adjacent lots for
adequate fire department vehicle access per the City of San Antonio
Fire Prevention Code. Any cross access shall not be blocked nor
may this note be removed from the plat without written permission
from the City of San Antonio Director of Development Services and
the San Antonio Fire Department Fire Marshal.
37.
Surveyor's Notes:
1. Property corners are monumented with a cap or disk marked
“surveyor’s name” unless noted otherwise; 2. coordinates shown are
based on the north American datum of 1983 (cors 1996) from the
Texas coordinate system established for the south central zone
displayed in grid values derived from the ngs cooperative cors
network; 3. dimensions shown are surface; and 4. bearings are
based on the north American datum of 1983 (cors 1996), from the
Texas coordinate system established for the south central zone.
38.Legal Instrument
35-B121(c)(20)
A legal instrument establishing a plan for the use and permanent
maintenance of the common areas/facilities designated on this plat is
being recorded on the same date as this plat.
39.
Townhouse
35-515(f)
All lots within this subdivision are restricted to townhouse use.
Page 8 of 8
40.
Zero Lot line
35-515(e)(2)
Five (5) foot wide maintenance easements are established within the
lots adjacent to all non-attached zero lot lines. Such easements shall
extend for the depth of the lot and are included in the deed
restrictions for all affected properties.
41.
Setback Required
OCL & optional ICL.
35-516(a)
The setbacks on this plat are imposed by the property owner or
Bexar County and are not subject to enforcement by the City of San
Antonio.
42.
Multiple page
Plat notes apply to every page of this multiple page plat.
43.
Tree Note
This subdivision is subject to a Master Tree Plan (AP # _____) which
requires compliance by the owners of all property within the plat
boundary, and their employees and contractors, and shall be binding
on all successors in title except for owners of single-family residential
lots subdivided hereunder
for which construction of a residential
structure has been completed. The Master Tree Plan is on file at the
City of San Antonio Arborists Office. No Trees or Understory shall be
removed without prior approval of the City Arborist Office per 35-
477(h).
44. Tree Save Area
35-523(e)(1)C.b)
Lot ____, Block ____, CB or NCB _____, (____ Ac.) is designated as
Tree Save Area. [may be plural]
45.
Conservation
Easement
35-441(a)(15)
In accordance with Unified Development Code provisions applicable
to conservation easements, Lots_____, Block______, CB or NCB
____, are dedicated as a conservation easement in perpetuity by
easement recorded in Volume____ ,Page____ and as such, are non-
buildable and limited to the uses enumerated in the easement.
46.
MAOZ
35-334(c)(5)
The property, either partially or wholly, lies within a military airport
overlay zone and is subject to noise and/or aircraft accident potential.
47.
Open Space
35-503(e) 35-B121(12)
Lot___, Block__, CB or NCB___, is designated as open space and
as a common area and a drainage, sewer, water, electric, gas,
telephone and cable TV easement. (Note: List all applicable
easements that fall within the open space area)
SHEET 1 OF X
SUBDIVISION PLAT NAME
Civil Job No. XXXX-XX; Survey Job No. XXXX-XX SUBDIVISION PLAT NAME HERE
SCALE: 1"= XX'
STATE OF TEXAS
COUNTY OF BEXAR
I HEREBY CERTIFY THAT PROPER ENGINEERING CONSIDERATION HAS BEEN GIVEN THIS
PLAT TO THE MATTERS OF STREETS, LOTS AND DRAINAGE LAYOUT. TO THE BEST OF MY
KNOWLEDGE THIS PLAT CONFORMS TO ALL REQUIREMENTS OF THE UNIFIED
DEVELOPMENT CODE, EXCEPT FOR THOSE VARIANCES GRANTED BY THE SAN
ANTONIO PLANNING COMMISSION.
__________________________________________________________
LICENSED PROFESSIONAL ENGINEER
STATE OF TEXAS
COUNTY OF BEXAR
I HEREBY CERTIFY THAT THE ABOVE PLAT CONFORMS TO THE MINIMUM STANDARDS SET
FORTH BY THE TEXAS BOARD OF PROFESSIONAL LAND SURVEYING ACCORDING TO AN
ACTUAL SURVEY MADE ON THE GROUND BY:
__________________________________________________________
REGISTERED PROFESSIONAL LAND SURVEYOR
ACREAGE OF AREA BEING REPLATTED WAS PREVIOUSLY PLATTED AS INSERT INFO HERE
OF THE NAME OF SUBDIVISION PLAT RECORDED IN VOLUME XXXX, PAGES XXX-XXX OF
THE DEED AND PLAT RECORDS OF BEXAR COUNTY, TEXAS. LIST ANY EASEMENTS BEING
REPLATTED
THIS PLAT OF SUBDIVISION PLAT NAME HERE HAS BEEN SUBMITTED TO AND
CONSIDERED BY THE PLANNING COMMISSION OF THE CITY OF SAN ANTONIO, TEXAS,
IS HEREBY APPROVED BY SUCH COMMISSION IN ACCORDANCE WITH STATE OR
LOCAL LAWS AND REGULATIONS; AND/OR WHERE ADMINISTRATIVE EXCEPTION(S)
AND/OR VARIANCE(S) HAVE BEEN GRANTED.
DATED THIS DAY OF , A.D. 20 .
BY: _____________________________________________________
CHAIRMAN
BY: _____________________________________________________
SECRETARY
AREA BEING REPLATTED
THROUGH PUBLIC HEARING
STATE OF TEXAS
COUNTY OF BEXAR
THE AREA BEING REPLATTED WAS PREVIOUSLY PLATTED ON PLAT (NAME AND NUMBER)
WHICH IS RECORDED IN VOLUME XXXX, PAGE(S) XXX-XXX, COUNTY PLAT AND DEED
RECORDS. THE SAN ANTONIO PLANNING COMMISSION AT ITS MEETING OF (DATE)
HELD A PUBLIC HEARING WHICH INVOLVED NOTIFICATION ON THE PROPOSED
REPLATTING OF THIS PROPERTY.
I(WE), THE OWNER(S) OF THE PROPERTY SHOWN ON THIS REPLAT HEREBY CERTIFY THAT
THIS REPLAT DOES NOT AMEND OR REMOVE ANY COVENANTS OR RESTRICTIONS.
__________________________________________________________________________________
OWNER/DEVELOPER: NAME HERE
COMPANY NAME HERE
ADDRESS HERE
CITY, STATE ZIP CODE
(XXX) XXX-XXXX
STATE OF TEXAS
COUNTY OF BEXAR
SWORN AND SUBSCRIBED BEFORE ME THIS THE ______ DAY OF ______________________,
A.D.
20 .
NOTARY PUBLIC IN AND FOR THE STATE OF TEXAS
MY COMMISSION EXPIRES: .
LOCATION MAP
NOT-TO-SCALE
STATE OF TEXAS
COUNTY OF BEXAR
BEFORE ME, THE UNDERSIGNED AUTHORITY ON THIS DAY PERSONALLY APPEARED
OWNER'S NAME HERE KNOWN TO ME TO BE THE PERSON WHOSE NAME IS
SUBSCRIBED TO THE FOREGOING INSTRUMENT, AND ACKNOWLEDGED TO ME THAT HE
EXECUTED THE SAME FOR THE PURPOSES AND CONSIDERATIONS THEREIN EXPRESSED
AND IN THE CAPACITY THEREIN STATED. GIVEN UNDER MY HAND AND SEAL OF OFFICE
THIS DAY OF , A.D. 20 .
__________________________________________________________
NOTARY PUBLIC, BEXAR COUNTY, TEXAS
STATE OF TEXAS
COUNTY OF BEXAR
THE OWNER OF LAND SHOWN ON THIS PLAT, IN PERSON OR THROUGH A DULY
AUTHORIZED AGENT, DEDICATES TO THE USE OF THE PUBLIC, EXCEPT AREAS IDENTIFIED
AS PRIVATE OR PART OF AN ENCLAVE OR PLANNED UNIT DEVELOPMENT, FOREVER ALL
STREETS, ALLEYS, PARKS, WATERCOURSES, DRAINS, EASEMENTS AND PUBLIC PLACES
THEREON SHOWN FOR THE PURPOSE AND CONSIDERATION THEREIN EXPRESSED.
_______________________________________________________________________________
OWNER/DEVELOPER: NAME HERE
COMPANY NAME HERE
ADDRESS HERE
CITY, STATE ZIP CODE
(XXX) XXX-XXXX
REPLAT & SUBDIVISION PLAT
ESTABLISHING
BEING A TOTAL OF ______ ACRES, BEING
(LOT AND BLOCK OF THE
ORIGINAL RECORDED SUBDIVISION (THAT ARE BEING CHANGED))
RECORDED IN VOLUME _____, PAGE _____ OF THE DEED AND PLAT
RECORDS OF BEXAR COUNTY, TEXAS AND
(A _____ ACRE TRACT OF LAND
OUT OF A __________ ACRE TRACT OF LAND RECORDED IN VOLUME _____,
PAGES _______ OF THE TYPE OF RECORDING DEVICE OF BEXAR COUNTY,
TEXAS, OUT OF THE NAME OF ORIGINAL SURVEY NUMBER _____, ABSTRACT
_____, COUNTY BLOCK _____,) ESTABLISHING LOTS & BLOCK, IN NEW CITY
BLOCK______, IN THE CITY OF SAN ANTONIO, BEXAR COUNTY, TEXAS.
WASTEWATER EDU NOTE:
THE NUMBER OF WASTEWATER EQUIVALENT DWELLING UNITS (EDUs) PAID FOR THIS
SUBDIVISION PLAT ARE KEPT ON FILE AT THE SAN ANTONIO WATER SYSTEM UNDER THE
PLAT NUMBER ISSUED BY THE DEVELOPMENT SERVICES DEPARTMENT.
DATE OF PREPARATION: March 23, 2018
FILE PATH HERE
CERTIFICATE OF APPROVAL
THE UNDERSIGNED, COUNTY JUDGE OF BEXAR COUNTY, TEXAS AND PRESIDING
OFFICER OF THE COMMISSIONERS COURT OF BEXAR COUNTY, DOES HEREBY CERTIFY
THAT THE ATTACHED PLAT WAS DULY FILED WITH THE COMMISSIONERS COURT OF
BEXAR COUNTY, TEXAS AND THAT AFTER EXAMINATION IT APPEARED THAT SAID PLAT IS
IN CONFORMITY WITH THE STATUTES, RULES AND REGULATIONS GOVERNING SAME,
AND THIS PLAT WAS APPROVED BY THE SAID COMMISSIONERS COURT.
DATED THIS ___________ DAY OF ________________________________ A.D. 20 ___________.
________________________________________________________________________________
COUNTY JUDGE, BEXAR COUNTY, TEXAS
________________________________________________________________________________
COUNTY CLERK, BEXAR COUNTY, TEXAS
SEE SHEET X OF X FOR LINE
AND CURVE TABLES
PLAT NOTES APPLY TO EVERY PAGE
OF THIS MULTIPLE PAGE PLAT
SITE
MAJOR ROAD (2 MAJOR THOROUGHFARES)
BEXAR
COUNTY
SHOW CITY LIMITS LINE (IF APPLICABLE)
SET 1/2" IRON ROD
FOUND MONUMENTATION
DOCUMENT NUMBER
REPETITIVE BEARING
AND/OR DISTANCE
PLANNED UNIT
DEVELOPMENT
INGRESS/EGRESS
INTERSECTION
MINIMUM FINISHED FLOOR ELEVATION
UNPLATTED
XXXX ACRES
OWNER: NAME HERE
(VOL XXXX, PG XXXX, DPR)
OVERHEAD ELECTRIC
LAND TIE/HOOK
1% ANNUAL CHANCE (100-YR) FUTURE CONDITIONS FLOODPLAIN
ORIGINAL SURVEY/COUNTY LINE
PROPOSED FEMA 1% ANNUAL CHANCE (100-YR) FLOODPLAIN
EFFECTIVE (EXISTING) FEMA 0.2% ANNUAL CHANCE (500-YR) FLOODPLAIN
OFFICIAL PUBLIC RECORDS
(OFFICIAL PUBLIC RECORDS
OF REAL PROPERTY) OF
BEXAR COUNTY, TEXAS
CITY OF SAN ANTONIO LIMITS
PROPOSED CONTOURS
EXISTING CONTOURS
EFFECTIVE (EXISTING) FEMA 1% ANNUAL CHANCE (100-YR) FLOODPLAIN
FOUND TxDOT
MONUMENTATION
FOUND 1/2" IRON ROD
(UNLESS NOTED OTHERWISE)
SIDEWALK CONSTRUCTED
WITH A PASSING SPACE
VEHICULAR NON-ACCESS
EASEMENT (NOT-TO-SCALE)
DENOTES ADDRESS OF LOT
ZERO LOT LINE
PRIVATE
SIGNAGE
TURNAROUND
RECYCLED WATER
WATER
PAGE(S)
VOLUME
VARIABLE WIDTH
STORM DRAINAGE
SANITARY SEWER
RADIAL BEARING
TELEPHONE
RIGHT-OF-WAY
BLOCK
MAP AND PLAT RECORDS OF
COMAL COUNTY, TEXAS
COMAL COUNTY DEED
AND PUBLIC RECORDS
CLEAR VISION
ARBITRARY
ACRE(S)
DEDICATION
DEED RECORDS OF BEXAR
COUNTY, TEXAS
DEED AND PLAT RECORDS OF
BEXAR COUNTY, TEXAS
GAS, ELECTRIC, TELEPHONE
AND CABLE TELEVISION
EXTRATERRITORIAL JURISDICTION
GREENBELT
FINISHED FLOOR ELEVATION
BUILDING SETBACK LINE
EASEMENT
CABLE TELEVISION
ELECTRIC
NEW CITY BLOCK
COUNTY BLOCK
LOT xxx, BLOCK xxx, NCB xxxxx
NAME OF SUBDIVISION
(VOL XXXX, PG XXXX, DPR)
EASEMENT TYPE HERE
(VOL XXXX, PG XXX-XXX, DPR)
EASEMENT TYPE HERE
(VOL XXXX, PG XXX-XXX, DPR)
EASEMENT TYPE
EASEMENT TYPE
EASEMENT TYPE
EASEMENT TYPE
EASEMENT TYPE
LEGEND
SET 1/2" IRON ROD ROW
CENTERLINE
PROPOSED EASEMENT
EXISTING EASEMENT
EXISTING LOT DATA
CPS/SAWS/COSA/UTILITY NOTE:
1. THE CITY OF SAN ANTONIO AS PART OF ITS ELECTRIC, GAS, WATER, AND WASTEWATER SYSTEMS - CITY PUBLIC SERVICE
BOARD (CPS ENERGY) AND SAN ANTONIO WATER SYSTEM (SAWS) - IS HEREBY DEDICATED EASEMENTS AND
RIGHTS-OF-WAY FOR UTILITY, TRANSMISSION, AND DISTRIBUTION INFRASTRUCTURE AND SERVICE FACILIITES IN THE AREAS
DESIGNATED ON THIS PLAT AS "ELECTRIC EASEMENT", "ANCHOR EASEMENT", "SERVICE EASEMENT", "OVERHANG
EASEMENT", "UTILITY EASEMENT", "GAS EASEMENT", "TRANSFORMER EASEMENT", "WATER EASEMENT", "SANITARY SEWER
EASEMENT" AND/OR "RECYCLED WATER EASEMENT" FOR THE PURPOSE OF INSTALLING, CONSTRUCTING,
RECONSTRUCTING, MAINTAINING, REMOVING, INSPECTING, PATROLLING, AND ERECTING UTILITY INFRASTRUCTURE AND
SERVICE FACILITIES FOR THE REASONS DESCRIBED ABOVE. CPS ENERGY AND SAWS SHALL ALSO HAVE THE RIGHT TO
RELOCATE SAID INFRASTRUCTURE AND SERVICE FACILITIES WITHIN EASEMENT AND RIGHT-OF-WAY AREAS, TOGETHER WITH
THE RIGHT OF INGRESS AND EGRESS OVER GRANTOR'S ADJACENT LANDS FOR THE PURPOSE OF ACCESSING SUCH
INFRASTRUCTURE AND SERVICE FACILITIES AND THE RIGHT TO REMOVE FROM SAID LANDS ALL TREES OR PARTS THEREOF,
OR OTHER OBSTRUCTIONS WHICH ENDANGER OR MAY INTERFERE WITH THE EFFICIENCY OF WATER, SEWER, GAS, AND/OR
ELECTRIC INFRASTRUCTURE AND SERVICE FACILITIES. NO BUILDINGS, STRUCTURES, CONCRETE SLABS, OR WALLS WILL BE
PLACED WITHIN EASEMENT AREAS WITHOUT AN ENCROACHMENT AGREEMENT WITH THE RESPECTIVE UTILITY.
2. ANY CPS ENERGY OR SAWS MONETARY LOSS RESULTING FROM MODIFICATIONS REQUIRED OF CPS ENERGY OR SAWS
INFRASTRUCTURE AND SERVICE FACILITIES, LOCATED WITHIN SAID EASEMENTS, DUE TO GRADE CHANGES OR GROUND
ELEVATION ALTERATIONS SHALL BE CHARGED TO THE PERSON OR PERSONS DEEMED RESPONSIBLE FOR SAID GRADE
CHANGES OR GROUND ELEVATION ALTERATIONS.
3. THIS PLAT DOES NOT AMEND, ALTER, RELEASE OR OTHERWISE AFFECT ANY EXISTING ELECTRIC, GAS, WATER, SEWER,
DRAINAGE, TELEPHONE, CABLE TV EASEMENTS OR ANY OTHER EASEMENTS FOR UTILITIES UNLESS THE CHANGES TO SUCH
EASEMENTS ARE DESCRIBED HEREON:
FOR SINGLE FAMILY RESIDENTIAL INCLUDE THE FOLLOWING:
4. CONCRETE DRIVEWAY APPROACHES ARE ALLOWED WITHIN THE FIVE (5) AND TEN (10) FOOT WIDE ELECTRIC AND GAS
EASEMENTS WHEN LOTS ARE SERVED ONLY BY UNDERGROUND ELECTRIC AND GAS FACILITIES.
5. ROOF OVERHANGS ARE ALLOWED WITHIN THE FIVE (5) AND TEN (10) FOOT WIDE ELECTRIC AND GAS EASEMENTS
WHEN ONLY UNDERGROUND ELECTRIC AND GAS FACILITIES ARE PROPOSED OR EXISTING WITHIN THOSE FIVE (5) AND TEN
(10) FOOT WIDE EASEMENTS.
AREA BEING REPLATTED
THROUGH PUBLIC HEARING
WITH WRITTEN NOTIFICATION
STATE OF TEXAS
COUNTY OF BEXAR
I, , COUNTY CLERK OF BEXAR COUNTY, DO HEREBY
CERTIFY THAT THIS PLAT WAS FILED FOR RECORD IN MY OFFICE, ON THE DAY
OF
, A.D. 20 AT M. AND DULY RECORDED THE
DAY OF , A.D. 20 AT M. IN THE
OFFICIAL PUBLIC RECORDS OF BEXAR COUNTY, TEXAS, IN BOOK/ VOLUME
ON PAGE IN TESTIMONY WHEREOF, WITNESS MY HAND AND OFFICIAL SEAL
OF OFFICE, THIS DAY OF , A.D. 20 .
COUNTY CLERK, BEXAR COUNTY, TEXAS
BY:
, DEPUTY
Bexar County Clerk's Recordation Template Block
is no longer needed as per their new system
generated recordation labels.
This area needs to have a minimum of 4 inches
in length and 2 1/2 inches high of blank space to
accommodate the new recording labels.
USE SIGNATURE BLOCK REQUIREMENTS
BELOW IF PLAT IS WITHIN BEXAR COUNTY:
LETTERING = 10 POINT FONT
DATE SPACING MINIMUM = 3/8” HIGH
SIGNATURE SPACING MINIMUM = 1 1/4” HIGH
MINIMUM SIGNATURE LINE LENGTH = 3”
MINIMUM DAY LENGTH = 1/2”
MINIMUM MONTH LENGTH = 1 1/2”
MINIMUM YEAR LENGTH = 1/3”
SHEET 1 OF X
SUBDIVISION PLAT
OF
SUBDIVISION PLAT NAME
Civil Job No. XXXX-XX; Survey Job No. XXXX-XX SUBDIVISION PLAT NAME HERE
STATE OF TEXAS
COUNTY OF BEXAR
I HEREBY CERTIFY THAT PROPER ENGINEERING CONSIDERATION HAS BEEN GIVEN THIS
PLAT TO THE MATTERS OF STREETS, LOTS AND DRAINAGE LAYOUT. TO THE BEST OF MY
KNOWLEDGE THIS PLAT CONFORMS TO ALL REQUIREMENTS OF THE UNIFIED
DEVELOPMENT CODE, EXCEPT FOR THOSE VARIANCES GRANTED BY THE SAN
ANTONIO PLANNING COMMISSION.
__________________________________________________________
LICENSED PROFESSIONAL ENGINEER
BEING A TOTAL OF_____ ACRE TRACT OF LAND OUT OF A __________ ACRE
TRACT OF LAND RECORDED IN VOLUME _____, PAGES _______ OF THE
TYPE
OF RECORDING DEVICE OF BEXAR COUNTY, TEXAS, OUT OF THE NAME OF
ORIGINAL SURVEY NUMBER _____, ABSTRACT _____, COUNTY BLOCK _____,
IN NEW CITY BLOCK______, IN THE CITY OF SAN ANTONIO, BEXAR COUNTY,
TEXAS. ESTABLISHING
LOTS & BLOCK.
LOCATION MAP
NOT-TO-SCALE
STATE OF TEXAS
COUNTY OF BEXAR
BEFORE ME, THE UNDERSIGNED AUTHORITY ON THIS DAY PERSONALLY APPEARED
OWNER'S NAME HERE KNOWN TO ME TO BE THE PERSON WHOSE NAME IS
SUBSCRIBED TO THE FOREGOING INSTRUMENT, AND ACKNOWLEDGED TO ME THAT HE
EXECUTED THE SAME FOR THE PURPOSES AND CONSIDERATIONS THEREIN EXPRESSED
AND IN THE CAPACITY THEREIN STATED. GIVEN UNDER MY HAND AND SEAL OF OFFICE
THIS DAY OF , A.D. 20 .
__________________________________________________________
NOTARY PUBLIC, BEXAR COUNTY, TEXAS
STATE OF TEXAS
COUNTY OF BEXAR
THE OWNER OF LAND SHOWN ON THIS PLAT, IN PERSON OR THROUGH A DULY
AUTHORIZED AGENT, DEDICATES TO THE USE OF THE PUBLIC, EXCEPT AREAS IDENTIFIED
AS PRIVATE OR PART OF AN ENCLAVE OR PLANNED UNIT DEVELOPMENT, FOREVER ALL
STREETS, ALLEYS, PARKS, WATERCOURSES, DRAINS, EASEMENTS AND PUBLIC PLACES
THEREON SHOWN FOR THE PURPOSE AND CONSIDERATION THEREIN EXPRESSED.
_______________________________________________________________________________
OWNER/DEVELOPER: NAME HERE
COMPANY NAME HERE
ADDRESS HERE
CITY, STATE ZIP CODE
(XXX) XXX-XXXX
TxDOT NOTES:
1. FOR RESIDENTIAL DEVELOPMENT DIRECTLY ADJACENT TO STATE RIGHT-OF-WAY, THE
DEVELOPER SHALL BE RESPONSIBLE FOR ADEQUATE SETBACK AND/OR SOUND
ABATEMENT MEASURES FOR FUTURE NOISE MITIGATION.
2. MAXIMUM ACCESS POINTS TO STATE HIGHWAY FROM THIS PROPERTY WILL BE
REGULATED AS DIRECTED BY "ACCESS MANAGEMENT MANUAL". THIS PROPERTY IS
ELIGIBLE FOR A MAXIMUM COMBINED TOTAL OF
NUMBER ACCESS POINTS ALONG
NAME OF STATE HWY, BASED ON OVERALL PLATTED HIGHWAY FRONTAGE OF
XXXX'.
3. IF SIDEWALKS ARE REQUIRED BY APPROPRIATE CITY ORDINANCE, A SIDEWALK
PERMIT MUST BE APPROVED BY TXDOT PRIOR TO CONSTRUCTION WITHIN STATE
RIGHT-OF-WAY. LOCATIONS OF SIDEWALKS WITHIN STATE RIGHT-OF-WAY SHALL BE
DIRECTED BY TXDOT.
CPS/SAWS/COSA/UTILITY NOTE:
1. THE CITY OF SAN ANTONIO AS PART OF ITS ELECTRIC, GAS, WATER, AND WASTEWATER SYSTEMS - CITY PUBLIC SERVICE
BOARD (CPS ENERGY) AND SAN ANTONIO WATER SYSTEM (SAWS) - IS HEREBY DEDICATED EASEMENTS AND
RIGHTS-OF-WAY FOR UTILITY, TRANSMISSION, AND DISTRIBUTION INFRASTRUCTURE AND SERVICE FACILIITES IN THE AREAS
DESIGNATED ON THIS PLAT AS "ELECTRIC EASEMENT", "ANCHOR EASEMENT", "SERVICE EASEMENT", "OVERHANG
EASEMENT", "UTILITY EASEMENT", "GAS EASEMENT", "TRANSFORMER EASEMENT", "WATER EASEMENT", "SANITARY SEWER
EASEMENT" AND/OR "RECYCLED WATER EASEMENT" FOR THE PURPOSE OF INSTALLING, CONSTRUCTING,
RECONSTRUCTING, MAINTAINING, REMOVING, INSPECTING, PATROLLING, AND ERECTING UTILITY INFRASTRUCTURE AND
SERVICE FACILITIES FOR THE REASONS DESCRIBED ABOVE. CPS ENERGY AND SAWS SHALL ALSO HAVE THE RIGHT TO
RELOCATE SAID INFRASTRUCTURE AND SERVICE FACILITIES WITHIN EASEMENT AND RIGHT-OF-WAY AREAS, TOGETHER WITH
THE RIGHT OF INGRESS AND EGRESS OVER GRANTOR'S ADJACENT LANDS FOR THE PURPOSE OF ACCESSING SUCH
INFRASTRUCTURE AND SERVICE FACILITIES AND THE RIGHT TO REMOVE FROM SAID LANDS ALL TREES OR PARTS THEREOF,
OR OTHER OBSTRUCTIONS WHICH ENDANGER OR MAY INTERFERE WITH THE EFFICIENCY OF WATER, SEWER, GAS, AND/OR
ELECTRIC INFRASTRUCTURE AND SERVICE FACILITIES. NO BUILDINGS, STRUCTURES, CONCRETE SLABS, OR WALLS WILL BE
PLACED WITHIN EASEMENT AREAS WITHOUT AN ENCROACHMENT AGREEMENT WITH THE RESPECTIVE UTILITY.
2. ANY CPS ENERGY OR SAWS MONETARY LOSS RESULTING FROM MODIFICATIONS REQUIRED OF CPS ENERGY OR SAWS
INFRASTRUCTURE AND SERVICE FACILITIES, LOCATED WITHIN SAID EASEMENTS, DUE TO GRADE CHANGES OR GROUND
ELEVATION ALTERATIONS SHALL BE CHARGED TO THE PERSON OR PERSONS DEEMED RESPONSIBLE FOR SAID GRADE
CHANGES OR GROUND ELEVATION ALTERATIONS.
3. THIS PLAT DOES NOT AMEND, ALTER, RELEASE OR OTHERWISE AFFECT ANY EXISTING ELECTRIC, GAS, WATER, SEWER,
DRAINAGE, TELEPHONE, CABLE TV EASEMENTS OR ANY OTHER EASEMENTS FOR UTILITIES UNLESS THE CHANGES TO SUCH
EASEMENTS ARE DESCRIBED HEREON:
FOR SINGLE FAMILY RESIDENTIAL INCLUDE THE FOLLOWING:
4. CONCRETE DRIVEWAY APPROACHES ARE ALLOWED WITHIN THE FIVE (5) AND TEN (10) FOOT WIDE ELECTRIC AND GAS
EASEMENTS WHEN LOTS ARE SERVED ONLY BY UNDERGROUND ELECTRIC AND GAS FACILITIES.
5. ROOF OVERHANGS ARE ALLOWED WITHIN THE FIVE (5) AND TEN (10) FOOT WIDE ELECTRIC AND GAS EASEMENTS
WHEN ONLY UNDERGROUND ELECTRIC AND GAS FACILITIES ARE PROPOSED OR EXISTING WITHIN THOSE FIVE (5) AND TEN
(10) FOOT WIDE EASEMENTS.
WASTEWATER EDU NOTE:
THE NUMBER OF WASTEWATER EQUIVALENT DWELLING UNITS (EDUs) PAID FOR THIS
SUBDIVISION PLAT ARE KEPT ON FILE AT THE SAN ANTONIO WATER SYSTEM UNDER THE
PLAT NUMBER ISSUED BY THE DEVELOPMENT SERVICES DEPARTMENT.
IMPACT FEE NOTE:
WATER AND/OR WASTEWATER IMPACT FEES WERE NOT PAID AT THE TIME OF PLATTING
FOR THIS PLAT. ALL IMPACT FEES MUST BE PAID PRIOR TO WATER METER SET AND/OR
PRIOR TO THE WASTEWATER SERVICE CONNECTION.
DATE OF PREPARATION: March 23, 2018
SEE SHEET X OF X FOR LINE
AND CURVE TABLES
PLAT NOTES APPLY TO EVERY PAGE
OF THIS MULTIPLE PAGE PLAT
FILE PATH HERE
THIS PLAT OF SUBDIVISION PLAT NAME HERE HAS BEEN SUBMITTED TO AND
CONSIDERED BY THE PLANNING COMMISSION OF THE CITY OF SAN ANTONIO, TEXAS,
IS HEREBY APPROVED BY SUCH COMMISSION IN ACCORDANCE WITH STATE OR
LOCAL LAWS AND REGULATIONS; AND/OR WHERE ADMINISTRATIVE EXCEPTION(S)
AND/OR VARIANCE(S) HAVE BEEN GRANTED.
DATED THIS DAY OF , A.D. 20 .
BY: _____________________________________________________
CHAIRMAN
BY: _____________________________________________________
SECRETARY
CERTIFICATE OF APPROVAL
THE UNDERSIGNED, COUNTY JUDGE OF BEXAR COUNTY, TEXAS AND PRESIDING
OFFICER OF THE COMMISSIONERS COURT OF BEXAR COUNTY, DOES HEREBY CERTIFY
THAT THE ATTACHED PLAT WAS DULY FILED WITH THE COMMISSIONERS COURT OF
BEXAR COUNTY, TEXAS AND THAT AFTER EXAMINATION IT APPEARED THAT SAID PLAT IS
IN CONFORMITY WITH THE STATUTES, RULES AND REGULATIONS GOVERNING SAME,
AND THIS PLAT WAS APPROVED BY THE SAID COMMISSIONERS COURT.
DATED THIS ___________ DAY OF ________________________________ A.D. 20 ___________.
________________________________________________________________________________
COUNTY JUDGE, BEXAR COUNTY, TEXAS
________________________________________________________________________________
COUNTY CLERK, BEXAR COUNTY, TEXAS
SITE
MAJOR ROAD (2 MAJOR THOROUGHFARES)
BEXAR
COUNTY
SHOW CITY LIMITS LINE (IF APPLICABLE)
STATE OF TEXAS
COUNTY OF BEXAR
I HEREBY CERTIFY THAT THE ABOVE PLAT CONFORMS TO THE MINIMUM STANDARDS SET
FORTH BY THE TEXAS BOARD OF PROFESSIONAL LAND SURVEYING ACCORDING TO AN
ACTUAL SURVEY MADE ON THE GROUND BY:
__________________________________________________________
REGISTERED PROFESSIONAL LAND SURVEYOR
SET 1/2" IRON ROD
FOUND MONUMENTATION
DOCUMENT NUMBER
REPETITIVE BEARING
AND/OR DISTANCE
PLANNED UNIT
DEVELOPMENT
INGRESS/EGRESS
INTERSECTION
MINIMUM FINISHED FLOOR ELEVATION
UNPLATTED
XXXX ACRES
OWNER: NAME HERE
(VOL XXXX, PG XXXX, DPR)
OVERHEAD ELECTRIC
LAND TIE/HOOK
1% ANNUAL CHANCE (100-YR) FUTURE CONDITIONS FLOODPLAIN
ORIGINAL SURVEY/COUNTY LINE
PROPOSED FEMA 1% ANNUAL CHANCE (100-YR) FLOODPLAIN
EFFECTIVE (EXISTING) FEMA 0.2% ANNUAL CHANCE (500-YR) FLOODPLAIN
OFFICIAL PUBLIC RECORDS
(OFFICIAL PUBLIC RECORDS
OF REAL PROPERTY) OF
BEXAR COUNTY, TEXAS
CITY OF SAN ANTONIO LIMITS
PROPOSED CONTOURS
EXISTING CONTOURS
EFFECTIVE (EXISTING) FEMA 1% ANNUAL CHANCE (100-YR) FLOODPLAIN
FOUND TxDOT
MONUMENTATION
FOUND 1/2" IRON ROD
(UNLESS NOTED OTHERWISE)
SIDEWALK CONSTRUCTED
WITH A PASSING SPACE
VEHICULAR NON-ACCESS
EASEMENT (NOT-TO-SCALE)
DENOTES ADDRESS OF LOT
ZERO LOT LINE
PRIVATE
SIGNAGE
TURNAROUND
RECYCLED WATER
WATER
PAGE(S)
VOLUME
VARIABLE WIDTH
STORM DRAINAGE
SANITARY SEWER
RADIAL BEARING
TELEPHONE
RIGHT-OF-WAY
BLOCK
MAP AND PLAT RECORDS OF
COMAL COUNTY, TEXAS
COMAL COUNTY DEED
AND PUBLIC RECORDS
CLEAR VISION
ARBITRARY
ACRE(S)
DEDICATION
DEED RECORDS OF BEXAR
COUNTY, TEXAS
DEED AND PLAT RECORDS OF
BEXAR COUNTY, TEXAS
GAS, ELECTRIC, TELEPHONE
AND CABLE TELEVISION
EXTRATERRITORIAL JURISDICTION
GREENBELT
FINISHED FLOOR ELEVATION
BUILDING SETBACK LINE
EASEMENT
CABLE TELEVISION
ELECTRIC
NEW CITY BLOCK
COUNTY BLOCK
LOT xxx, BLOCK xxx, NCB xxxxx
NAME OF SUBDIVISION
(VOL XXXX, PG XXXX, DPR)
EASEMENT TYPE HERE
(VOL XXXX, PG XXX-XXX, DPR)
EASEMENT TYPE HERE
(VOL XXXX, PG XXX-XXX, DPR)
EASEMENT TYPE
EASEMENT TYPE
EASEMENT TYPE
EASEMENT TYPE
EASEMENT TYPE
LEGEND
SET 1/2" IRON ROD ROW
CENTERLINE
PROPOSED EASEMENT
EXISTING EASEMENT
EXISTING LOT DATA
STATE OF TEXAS
COUNTY OF BEXAR
I, , COUNTY CLERK OF BEXAR COUNTY, DO HEREBY
CERTIFY THAT THIS PLAT WAS FILED FOR RECORD IN MY OFFICE, ON THE DAY
OF
, A.D. 20 AT M. AND DULY RECORDED THE
DAY OF , A.D. 20 AT M. IN THE
OFFICIAL PUBLIC RECORDS OF BEXAR COUNTY, TEXAS, IN BOOK/ VOLUME
ON PAGE IN TESTIMONY WHEREOF, WITNESS MY HAND AND OFFICIAL SEAL
OF OFFICE, THIS DAY OF , A.D. 20 .
COUNTY CLERK, BEXAR COUNTY, TEXAS
BY:
, DEPUTY
SHOW ETJ LINE (IF APPLICABLE)
Bexar County Clerk's Recordation Template Block
is no longer needed as per their new system
generated recordation labels.
This area needs to have a minimum of 4 inches
in length and 2 1/2 inches high of blank space to
accommodate the new recording labels.
USE SIGNATURE BLOCK REQUIREMENTS
BELOW IF PLAT IS WITHIN BEXAR COUNTY:
LETTERING = 10 POINT FONT
DATE SPACING MINIMUM = 3/8” HIGH
SIGNATURE SPACING MINIMUM = 1 1/4” HIGH
MINIMUM SIGNATURE LINE LENGTH = 3”
MINIMUM DAY LENGTH = 1/2”
MINIMUM MONTH LENGTH = 1 1/2”
MINIMUM YEAR LENGTH = 1/3”
THIS
PLAT OF SUBDIVISION PLAT NAME HERE HAS BEEN SUBMITTED TO THE CITY
OF SAN ANTONIO, TEXAS, AND HAVING BEEN REVIEWED BY THE DIRECTOR OF
DEVELOPMENT SERVICES, IS HEREBY APPROVED IN ACCORDANCE WITH STATE OR
LOCAL LAWS AND REGULATIONS; AND/OR WHERE ADMINISTRATIVE EXCEPTION(S)
HAVE BEEN GRANTED.
DATED THIS DAY OF , A.D. 20 .
BY: _____________________________________________________
DIRECTOR OF DEVELOPMENT SERVICES
SHEET 1 OF X
SUBDIVISION PLAT
OF
SUBDIVISION PLAT NAME
Civil Job No. XXXX-XX; Survey Job No. XXXX-XX SUBDIVISION PLAT NAME HERE
STATE OF TEXAS
COUNTY OF BEXAR
I HEREBY CERTIFY THAT PROPER ENGINEERING CONSIDERATION HAS BEEN GIVEN THIS
PLAT TO THE MATTERS OF STREETS, LOTS AND DRAINAGE LAYOUT. TO THE BEST OF MY
KNOWLEDGE THIS PLAT CONFORMS TO ALL REQUIREMENTS OF THE UNIFIED
DEVELOPMENT CODE, EXCEPT FOR THOSE VARIANCES GRANTED BY THE SAN
ANTONIO PLANNING COMMISSION.
__________________________________________________________
LICENSED PROFESSIONAL ENGINEER
BEING A TOTAL OF_____ ACRE TRACT OF LAND OUT OF A __________ ACRE
TRACT OF LAND RECORDED IN VOLUME _____, PAGES _______ OF THE
TYPE
OF RECORDING DEVICE OF BEXAR COUNTY, TEXAS, OUT OF THE NAME OF
ORIGINAL SURVEY NUMBER _____, ABSTRACT _____, COUNTY BLOCK _____,
IN NEW CITY BLOCK______, IN THE CITY OF SAN ANTONIO, BEXAR COUNTY,
TEXAS. ESTABLISHING
LOTS & BLOCK.
LOCATION MAP
NOT-TO-SCALE
STATE OF TEXAS
COUNTY OF BEXAR
BEFORE ME, THE UNDERSIGNED AUTHORITY ON THIS DAY PERSONALLY APPEARED
OWNER'S NAME HERE KNOWN TO ME TO BE THE PERSON WHOSE NAME IS
SUBSCRIBED TO THE FOREGOING INSTRUMENT, AND ACKNOWLEDGED TO ME THAT HE
EXECUTED THE SAME FOR THE PURPOSES AND CONSIDERATIONS THEREIN EXPRESSED
AND IN THE CAPACITY THEREIN STATED. GIVEN UNDER MY HAND AND SEAL OF OFFICE
THIS DAY OF , A.D. 20 .
__________________________________________________________
NOTARY PUBLIC, BEXAR COUNTY, TEXAS
STATE OF TEXAS
COUNTY OF BEXAR
THE OWNER OF LAND SHOWN ON THIS PLAT, IN PERSON OR THROUGH A DULY
AUTHORIZED AGENT, DEDICATES TO THE USE OF THE PUBLIC, EXCEPT AREAS IDENTIFIED
AS PRIVATE OR PART OF AN ENCLAVE OR PLANNED UNIT DEVELOPMENT, FOREVER ALL
STREETS, ALLEYS, PARKS, WATERCOURSES, DRAINS, EASEMENTS AND PUBLIC PLACES
THEREON SHOWN FOR THE PURPOSE AND CONSIDERATION THEREIN EXPRESSED.
_______________________________________________________________________________
OWNER/DEVELOPER: NAME HERE
COMPANY NAME HERE
ADDRESS HERE
CITY, STATE ZIP CODE
(XXX) XXX-XXXX
TxDOT NOTES:
1. FOR RESIDENTIAL DEVELOPMENT DIRECTLY ADJACENT TO STATE RIGHT-OF-WAY, THE
DEVELOPER SHALL BE RESPONSIBLE FOR ADEQUATE SETBACK AND/OR SOUND
ABATEMENT MEASURES FOR FUTURE NOISE MITIGATION.
2. MAXIMUM ACCESS POINTS TO STATE HIGHWAY FROM THIS PROPERTY WILL BE
REGULATED AS DIRECTED BY "ACCESS MANAGEMENT MANUAL". THIS PROPERTY IS
ELIGIBLE FOR A MAXIMUM COMBINED TOTAL OF
NUMBER ACCESS POINTS ALONG
NAME OF STATE HWY, BASED ON OVERALL PLATTED HIGHWAY FRONTAGE OF
XXXX'.
3. IF SIDEWALKS ARE REQUIRED BY APPROPRIATE CITY ORDINANCE, A SIDEWALK
PERMIT MUST BE APPROVED BY TXDOT PRIOR TO CONSTRUCTION WITHIN STATE
RIGHT-OF-WAY. LOCATIONS OF SIDEWALKS WITHIN STATE RIGHT-OF-WAY SHALL BE
DIRECTED BY TXDOT.
DATE OF PREPARATION: March 23, 2018
SEE SHEET X OF X FOR LINE
AND CURVE TABLES
PLAT NOTES APPLY TO EVERY PAGE
OF THIS MULTIPLE PAGE PLAT
FILE PATH HERE
CERTIFICATE OF APPROVAL
THIS AMENDING PLAT HAS BEEN SUBMITTED TO BEXAR COUNTY, TEXAS PUBLIC WORKS
DEPARTMENT AND HAVING BEEN REVIEWED BY THE DIRECTOR OF PUBLIC
WORKS / COUNTY ENGINEER, IS HEREBY APPROVED IN ACCORDANCE WITH STATE
AND LOCAL LAWS AND REGULATIONS AS INDICATED BELOW.
ON THIS ____________ DAY OF ________________________________ A.D. 20 ____________.
________________________________________________________________________________
DIRECTOR OF PUBLIC WORKS / COUNTY ENGINEER, BEXAR COUNTY, TEXAS
SITE
MAJOR ROAD (2 MAJOR THOROUGHFARES)
BEXAR
COUNTY
SHOW CITY LIMITS LINE (IF APPLICABLE)
STATE OF TEXAS
COUNTY OF BEXAR
I HEREBY CERTIFY THAT THE ABOVE PLAT CONFORMS TO THE MINIMUM STANDARDS SET
FORTH BY THE TEXAS BOARD OF PROFESSIONAL LAND SURVEYING ACCORDING TO AN
ACTUAL SURVEY MADE ON THE GROUND BY:
__________________________________________________________
REGISTERED PROFESSIONAL LAND SURVEYOR
CPS/SAWS/COSA/UTILITY NOTE:
1. THE CITY OF SAN ANTONIO AS PART OF ITS ELECTRIC, GAS, WATER, AND WASTEWATER SYSTEMS - CITY PUBLIC SERVICE
BOARD (CPS ENERGY) AND SAN ANTONIO WATER SYSTEM (SAWS) - IS HEREBY DEDICATED EASEMENTS AND
RIGHTS-OF-WAY FOR UTILITY, TRANSMISSION, AND DISTRIBUTION INFRASTRUCTURE AND SERVICE FACILIITES IN THE AREAS
DESIGNATED ON THIS PLAT AS "ELECTRIC EASEMENT", "ANCHOR EASEMENT", "SERVICE EASEMENT", "OVERHANG
EASEMENT", "UTILITY EASEMENT", "GAS EASEMENT", "TRANSFORMER EASEMENT", "WATER EASEMENT", "SANITARY SEWER
EASEMENT" AND/OR "RECYCLED WATER EASEMENT" FOR THE PURPOSE OF INSTALLING, CONSTRUCTING,
RECONSTRUCTING, MAINTAINING, REMOVING, INSPECTING, PATROLLING, AND ERECTING UTILITY INFRASTRUCTURE AND
SERVICE FACILITIES FOR THE REASONS DESCRIBED ABOVE. CPS ENERGY AND SAWS SHALL ALSO HAVE THE RIGHT TO
RELOCATE SAID INFRASTRUCTURE AND SERVICE FACILITIES WITHIN EASEMENT AND RIGHT-OF-WAY AREAS, TOGETHER WITH
THE RIGHT OF INGRESS AND EGRESS OVER GRANTOR'S ADJACENT LANDS FOR THE PURPOSE OF ACCESSING SUCH
INFRASTRUCTURE AND SERVICE FACILITIES AND THE RIGHT TO REMOVE FROM SAID LANDS ALL TREES OR PARTS THEREOF,
OR OTHER OBSTRUCTIONS WHICH ENDANGER OR MAY INTERFERE WITH THE EFFICIENCY OF WATER, SEWER, GAS, AND/OR
ELECTRIC INFRASTRUCTURE AND SERVICE FACILITIES. NO BUILDINGS, STRUCTURES, CONCRETE SLABS, OR WALLS WILL BE
PLACED WITHIN EASEMENT AREAS WITHOUT AN ENCROACHMENT AGREEMENT WITH THE RESPECTIVE UTILITY.
2. ANY CPS ENERGY OR SAWS MONETARY LOSS RESULTING FROM MODIFICATIONS REQUIRED OF CPS ENERGY OR SAWS
INFRASTRUCTURE AND SERVICE FACILITIES, LOCATED WITHIN SAID EASEMENTS, DUE TO GRADE CHANGES OR GROUND
ELEVATION ALTERATIONS SHALL BE CHARGED TO THE PERSON OR PERSONS DEEMED RESPONSIBLE FOR SAID GRADE
CHANGES OR GROUND ELEVATION ALTERATIONS.
3. THIS PLAT DOES NOT AMEND, ALTER, RELEASE OR OTHERWISE AFFECT ANY EXISTING ELECTRIC, GAS, WATER, SEWER,
DRAINAGE, TELEPHONE, CABLE TV EASEMENTS OR ANY OTHER EASEMENTS FOR UTILITIES UNLESS THE CHANGES TO SUCH
EASEMENTS ARE DESCRIBED HEREON:
FOR SINGLE FAMILY RESIDENTIAL INCLUDE THE FOLLOWING:
4. CONCRETE DRIVEWAY APPROACHES ARE ALLOWED WITHIN THE FIVE (5) AND TEN (10) FOOT WIDE ELECTRIC AND GAS
EASEMENTS WHEN LOTS ARE SERVED ONLY BY UNDERGROUND ELECTRIC AND GAS FACILITIES.
5. ROOF OVERHANGS ARE ALLOWED WITHIN THE FIVE (5) AND TEN (10) FOOT WIDE ELECTRIC AND GAS EASEMENTS
WHEN ONLY UNDERGROUND ELECTRIC AND GAS FACILITIES ARE PROPOSED OR EXISTING WITHIN THOSE FIVE (5) AND TEN
(10) FOOT WIDE EASEMENTS.
WASTEWATER EDU NOTE:
THE NUMBER OF WASTEWATER EQUIVALENT DWELLING UNITS (EDUs) PAID FOR THIS
SUBDIVISION PLAT ARE KEPT ON FILE AT THE SAN ANTONIO WATER SYSTEM UNDER THE
PLAT NUMBER ISSUED BY THE DEVELOPMENT SERVICES DEPARTMENT.
IMPACT FEE NOTE:
WATER AND/OR WASTEWATER IMPACT FEES WERE NOT PAID AT THE TIME OF PLATTING
FOR THIS PLAT. ALL IMPACT FEES MUST BE PAID PRIOR TO WATER METER SET AND/OR
PRIOR TO THE WASTEWATER SERVICE CONNECTION.
SET 1/2" IRON ROD
FOUND MONUMENTATION
DOCUMENT NUMBER
REPETITIVE BEARING
AND/OR DISTANCE
PLANNED UNIT
DEVELOPMENT
INGRESS/EGRESS
INTERSECTION
MINIMUM FINISHED FLOOR ELEVATION
UNPLATTED
XXXX ACRES
OWNER: NAME HERE
(VOL XXXX, PG XXXX, DPR)
OVERHEAD ELECTRIC
LAND TIE/HOOK
1% ANNUAL CHANCE (100-YR) FUTURE CONDITIONS FLOODPLAIN
ORIGINAL SURVEY/COUNTY LINE
PROPOSED FEMA 1% ANNUAL CHANCE (100-YR) FLOODPLAIN
EFFECTIVE (EXISTING) FEMA 0.2% ANNUAL CHANCE (500-YR) FLOODPLAIN
OFFICIAL PUBLIC RECORDS
(OFFICIAL PUBLIC RECORDS
OF REAL PROPERTY) OF
BEXAR COUNTY, TEXAS
CITY OF SAN ANTONIO LIMITS
PROPOSED CONTOURS
EXISTING CONTOURS
EFFECTIVE (EXISTING) FEMA 1% ANNUAL CHANCE (100-YR) FLOODPLAIN
FOUND TxDOT
MONUMENTATION
FOUND 1/2" IRON ROD
(UNLESS NOTED OTHERWISE)
SIDEWALK CONSTRUCTED
WITH A PASSING SPACE
VEHICULAR NON-ACCESS
EASEMENT (NOT-TO-SCALE)
DENOTES ADDRESS OF LOT
ZERO LOT LINE
PRIVATE
SIGNAGE
TURNAROUND
RECYCLED WATER
WATER
PAGE(S)
VOLUME
VARIABLE WIDTH
STORM DRAINAGE
SANITARY SEWER
RADIAL BEARING
TELEPHONE
RIGHT-OF-WAY
BLOCK
MAP AND PLAT RECORDS OF
COMAL COUNTY, TEXAS
COMAL COUNTY DEED
AND PUBLIC RECORDS
CLEAR VISION
ARBITRARY
ACRE(S)
DEDICATION
DEED RECORDS OF BEXAR
COUNTY, TEXAS
DEED AND PLAT RECORDS OF
BEXAR COUNTY, TEXAS
GAS, ELECTRIC, TELEPHONE
AND CABLE TELEVISION
EXTRATERRITORIAL JURISDICTION
GREENBELT
FINISHED FLOOR ELEVATION
BUILDING SETBACK LINE
EASEMENT
CABLE TELEVISION
ELECTRIC
NEW CITY BLOCK
COUNTY BLOCK
LOT xxx, BLOCK xxx, NCB xxxxx
NAME OF SUBDIVISION
(VOL XXXX, PG XXXX, DPR)
EASEMENT TYPE HERE
(VOL XXXX, PG XXX-XXX, DPR)
EASEMENT TYPE HERE
(VOL XXXX, PG XXX-XXX, DPR)
EASEMENT TYPE
EASEMENT TYPE
EASEMENT TYPE
EASEMENT TYPE
EASEMENT TYPE
LEGEND
SET 1/2" IRON ROD ROW
CENTERLINE
PROPOSED EASEMENT
EXISTING EASEMENT
EXISTING LOT DATA
STATE OF TEXAS
COUNTY OF BEXAR
I, , COUNTY CLERK OF BEXAR COUNTY, DO HEREBY
CERTIFY THAT THIS PLAT WAS FILED FOR RECORD IN MY OFFICE, ON THE DAY
OF
, A.D. 20 AT M. AND DULY RECORDED THE
DAY OF , A.D. 20 AT M. IN THE
OFFICIAL PUBLIC RECORDS OF BEXAR COUNTY, TEXAS, IN BOOK/ VOLUME
ON PAGE IN TESTIMONY WHEREOF, WITNESS MY HAND AND OFFICIAL SEAL
OF OFFICE, THIS DAY OF , A.D. 20 .
COUNTY CLERK, BEXAR COUNTY, TEXAS
BY:
, DEPUTY
SHOW ETJ LINE (IF APPLICABLE)
Bexar County Clerk's Recordation Template Block
is no longer needed as per their new system
generated recordation labels.
This area needs to have a minimum of 4 inches
in length and 2 1/2 inches high of blank space to
accommodate the new recording labels.
USE SIGNATURE BLOCK REQUIREMENTS
BELOW IF PLAT IS WITHIN BEXAR COUNTY:
LETTERING = 10 POINT FONT
DATE SPACING MINIMUM = 3/8” HIGH
SIGNATURE SPACING MINIMUM = 1/2” HIGH
MINIMUM SIGNATURE LINE LENGTH = 3”
MINIMUM DAY LENGTH = 1/2”
MINIMUM MONTH LENGTH = 1 1/2”
MINIMUM YEAR LENGTH = 1/3”
SHEET 1 OF X
LOCATION MAP
SITE
MAJOR ROAD (2 MAJOR THOROUGHFARES)
BEXAR
COUNTY
SHOW CITY LIMITS LINE (IF APPLICABLE)
NOT-TO-SCALE
AMENDING PLAT OF
SUBDIVISION PLAT NAME
THIS PLAT AMENDS LOT, BLOCK AND NCB INFO HERE OF THE PLAT NAME
HERE SUBDIVISION, PREVIOUSLY RECORDED IN VOLUME XXXX, PAGES XX-XX
OF THE DEED AND PLAT RECORDS OF BEXAR COUNTY, TEXAS.
Civil Job No. XXXX-XX; Survey Job No. XXXX-XX SUBDIVISION PLAT NAME HERE
STATE OF TEXAS
COUNTY OF BEXAR
BEFORE ME, THE UNDERSIGNED AUTHORITY ON THIS DAY PERSONALLY APPEARED
OWNER'S NAME HERE KNOWN TO ME TO BE THE PERSON WHOSE NAME IS
SUBSCRIBED TO THE FOREGOING INSTRUMENT, AND ACKNOWLEDGED TO ME THAT HE
EXECUTED THE SAME FOR THE PURPOSES AND CONSIDERATIONS THEREIN EXPRESSED
AND IN THE CAPACITY THEREIN STATED. GIVEN UNDER MY HAND AND SEAL OF OFFICE
THIS DAY OF , A.D. 20 .
__________________________________________________________
NOTARY PUBLIC, BEXAR COUNTY, TEXAS
STATE OF TEXAS
COUNTY OF BEXAR
I HEREBY CERTIFY THAT PROPER ENGINEERING CONSIDERATION HAS BEEN GIVEN THIS
PLAT TO THE MATTERS OF STREETS, LOTS AND DRAINAGE LAYOUT. TO THE BEST OF MY
KNOWLEDGE THIS PLAT CONFORMS TO ALL REQUIREMENTS OF THE UNIFIED
DEVELOPMENT CODE, EXCEPT FOR THOSE VARIANCES GRANTED BY THE SAN
ANTONIO PLANNING COMMISSION.
__________________________________________________________
LICENSED PROFESSIONAL ENGINEER
SCALE: 1"= XX'
AREA BEING AMENDED
XXX ACRES BEING AMENDED WAS PREVIOUSLY PLATTED AS INSERT INFO HERE OF THE
NAME OF SUBDIVISION PLAT RECORDED IN VOLUME XXXX, PAGES XXX-XXX OF THE
DEED AND PLAT RECORDS OF BEXAR COUNTY, TEXAS.
REASON FOR AMENDING:
SECTION 35-XXX (x)(11): LIST THE REASONS HERE AS STATED IN THE UNIFIED
DEVELOPMENT CODE WHY THIS PLAT IS BEING AMENDED. EXAMPLE:
TO REPLAT ONE OR MORE LOTS FRONTING ON AN EXISTING STREET IF: (A) THE OWNERS
OF ALL THOSE LOTS JOIN IN THE APPLICATION FOR AMENDING THE PLAT; (B) THE
AMENDMENT DOES NOT ATTEMPT TO REMOVE RECORDED COVENANTS OR
RESTRICTIONS; (C) THE AMENDMENT DOES NOT INCREASE THE NUMBER OF LOTS; (D)
THE AMENDMENT DOES NOT CREATE OR REQUIRE THE CREATION OF A NEW STREET OR
MAKE NECESSARY THE EXTENSION OF MUNICIPAL FACILITIES.
AMENDMENTS ARE AS FOLLOWS:
LIST REASONS HERE.
STATE OF TEXAS
COUNTY OF BEXAR
THE OWNER OF LAND SHOWN ON THIS PLAT, IN PERSON OR THROUGH A DULY
AUTHORIZED AGENT, DEDICATES TO THE USE OF THE PUBLIC, EXCEPT AREAS IDENTIFIED
AS PRIVATE OR PART OF AN ENCLAVE OR PLANNED UNIT DEVELOPMENT, FOREVER ALL
STREETS, ALLEYS, PARKS, WATERCOURSES, DRAINS, EASEMENTS AND PUBLIC PLACES
THEREON SHOWN FOR THE PURPOSE AND CONSIDERATION THEREIN EXPRESSED.
_______________________________________________________________________________
OWNER/DEVELOPER: NAME HERE
COMPANY NAME HERE
ADDRESS HERE
CITY, STATE ZIP CODE
(XXX) XXX-XXXX
DATE OF PREPARATION: March 23, 2018
SEE SHEET X OF X FOR LINE
AND CURVE TABLES
PLAT NOTES APPLY TO EVERY PAGE
OF THIS MULTIPLE PAGE PLAT
CERTIFICATE OF APPROVAL
THIS AMENDING PLAT HAS BEEN SUBMITTED TO BEXAR COUNTY, TEXAS PUBLIC WORKS
DEPARTMENT AND HAVING BEEN REVIEWED BY THE DIRECTOR OF PUBLIC
WORKS / COUNTY ENGINEER, IS HEREBY APPROVED IN ACCORDANCE WITH STATE
AND LOCAL LAWS AND REGULATIONS AS INDICATED BELOW.
ON THIS ____________ DAY OF ________________________________ A.D. 20 ____________.
________________________________________________________________________________
DIRECTOR OF PUBLIC WORKS / COUNTY ENGINEER, BEXAR COUNTY, TEXAS
THIS PLAT OF
SUBDIVISION PLAT NAME HERE HAS BEEN SUBMITTED TO THE CITY
OF SAN ANTONIO, TEXAS, AND HAVING BEEN REVIEWED BY THE DIRECTOR OF
DEVELOPMENT SERVICES, IS HEREBY APPROVED IN ACCORDANCE WITH STATE OR
LOCAL LAWS AND REGULATIONS; AND/OR WHERE ADMINISTRATIVE EXCEPTION(S)
HAVE BEEN GRANTED.
DATED THIS
DAY OF , A.D. 20 .
BY: _____________________________________________________
DIRECTOR OF DEVELOPMENT SERVICES
FILE PATH HERE
STATE OF TEXAS
COUNTY OF BEXAR
I HEREBY CERTIFY THAT THE ABOVE PLAT CONFORMS TO THE MINIMUM STANDARDS SET
FORTH BY THE TEXAS BOARD OF PROFESSIONAL LAND SURVEYING ACCORDING TO AN
ACTUAL SURVEY MADE ON THE GROUND BY:
__________________________________________________________
REGISTERED PROFESSIONAL LAND SURVEYOR
WASTEWATER EDU NOTE:
THE NUMBER OF WASTEWATER EQUIVALENT DWELLING UNITS (EDUs) PAID FOR THIS
SUBDIVISION PLAT ARE KEPT ON FILE AT THE SAN ANTONIO WATER SYSTEM UNDER THE
PLAT NUMBER ISSUED BY THE DEVELOPMENT SERVICES DEPARTMENT.
SET 1/2" IRON ROD
FOUND MONUMENTATION
DOCUMENT NUMBER
REPETITIVE BEARING
AND/OR DISTANCE
PLANNED UNIT
DEVELOPMENT
INGRESS/EGRESS
INTERSECTION
MINIMUM FINISHED FLOOR ELEVATION
UNPLATTED
XXXX ACRES
OWNER: NAME HERE
(VOL XXXX, PG XXXX, DPR)
OVERHEAD ELECTRIC
LAND TIE/HOOK
1% ANNUAL CHANCE (100-YR) FUTURE CONDITIONS FLOODPLAIN
ORIGINAL SURVEY/COUNTY LINE
PROPOSED FEMA 1% ANNUAL CHANCE (100-YR) FLOODPLAIN
EFFECTIVE (EXISTING) FEMA 0.2% ANNUAL CHANCE (500-YR) FLOODPLAIN
OFFICIAL PUBLIC RECORDS
(OFFICIAL PUBLIC RECORDS
OF REAL PROPERTY) OF
BEXAR COUNTY, TEXAS
CITY OF SAN ANTONIO LIMITS
PROPOSED CONTOURS
EXISTING CONTOURS
EFFECTIVE (EXISTING) FEMA 1% ANNUAL CHANCE (100-YR) FLOODPLAIN
FOUND TxDOT
MONUMENTATION
FOUND 1/2" IRON ROD
(UNLESS NOTED OTHERWISE)
SIDEWALK CONSTRUCTED
WITH A PASSING SPACE
VEHICULAR NON-ACCESS
EASEMENT (NOT-TO-SCALE)
DENOTES ADDRESS OF LOT
ZERO LOT LINE
PRIVATE
SIGNAGE
TURNAROUND
RECYCLED WATER
WATER
PAGE(S)
VOLUME
VARIABLE WIDTH
STORM DRAINAGE
SANITARY SEWER
RADIAL BEARING
TELEPHONE
RIGHT-OF-WAY
BLOCK
MAP AND PLAT RECORDS OF
COMAL COUNTY, TEXAS
COMAL COUNTY DEED
AND PUBLIC RECORDS
CLEAR VISION
ARBITRARY
ACRE(S)
DEDICATION
DEED RECORDS OF BEXAR
COUNTY, TEXAS
DEED AND PLAT RECORDS OF
BEXAR COUNTY, TEXAS
GAS, ELECTRIC, TELEPHONE
AND CABLE TELEVISION
EXTRATERRITORIAL JURISDICTION
GREENBELT
FINISHED FLOOR ELEVATION
BUILDING SETBACK LINE
EASEMENT
CABLE TELEVISION
ELECTRIC
NEW CITY BLOCK
COUNTY BLOCK
LOT xxx, BLOCK xxx, NCB xxxxx
NAME OF SUBDIVISION
(VOL XXXX, PG XXXX, DPR)
EASEMENT TYPE HERE
(VOL XXXX, PG XXX-XXX, DPR)
EASEMENT TYPE HERE
(VOL XXXX, PG XXX-XXX, DPR)
EASEMENT TYPE
EASEMENT TYPE
EASEMENT TYPE
EASEMENT TYPE
EASEMENT TYPE
LEGEND
SET 1/2" IRON ROD ROW
CENTERLINE
PROPOSED EASEMENT
EXISTING EASEMENT
EXISTING LOT DATA
CPS/SAWS/COSA/UTILITY NOTE:
1. THE CITY OF SAN ANTONIO AS PART OF ITS ELECTRIC, GAS, WATER, AND WASTEWATER SYSTEMS - CITY PUBLIC SERVICE
BOARD (CPS ENERGY) AND SAN ANTONIO WATER SYSTEM (SAWS) - IS HEREBY DEDICATED EASEMENTS AND
RIGHTS-OF-WAY FOR UTILITY, TRANSMISSION, AND DISTRIBUTION INFRASTRUCTURE AND SERVICE FACILIITES IN THE AREAS
DESIGNATED ON THIS PLAT AS "ELECTRIC EASEMENT", "ANCHOR EASEMENT", "SERVICE EASEMENT", "OVERHANG
EASEMENT", "UTILITY EASEMENT", "GAS EASEMENT", "TRANSFORMER EASEMENT", "WATER EASEMENT", "SANITARY SEWER
EASEMENT" AND/OR "RECYCLED WATER EASEMENT" FOR THE PURPOSE OF INSTALLING, CONSTRUCTING,
RECONSTRUCTING, MAINTAINING, REMOVING, INSPECTING, PATROLLING, AND ERECTING UTILITY INFRASTRUCTURE AND
SERVICE FACILITIES FOR THE REASONS DESCRIBED ABOVE. CPS ENERGY AND SAWS SHALL ALSO HAVE THE RIGHT TO
RELOCATE SAID INFRASTRUCTURE AND SERVICE FACILITIES WITHIN EASEMENT AND RIGHT-OF-WAY AREAS, TOGETHER WITH
THE RIGHT OF INGRESS AND EGRESS OVER GRANTOR'S ADJACENT LANDS FOR THE PURPOSE OF ACCESSING SUCH
INFRASTRUCTURE AND SERVICE FACILITIES AND THE RIGHT TO REMOVE FROM SAID LANDS ALL TREES OR PARTS THEREOF,
OR OTHER OBSTRUCTIONS WHICH ENDANGER OR MAY INTERFERE WITH THE EFFICIENCY OF WATER, SEWER, GAS, AND/OR
ELECTRIC INFRASTRUCTURE AND SERVICE FACILITIES. NO BUILDINGS, STRUCTURES, CONCRETE SLABS, OR WALLS WILL BE
PLACED WITHIN EASEMENT AREAS WITHOUT AN ENCROACHMENT AGREEMENT WITH THE RESPECTIVE UTILITY.
2. ANY CPS ENERGY OR SAWS MONETARY LOSS RESULTING FROM MODIFICATIONS REQUIRED OF CPS ENERGY OR SAWS
INFRASTRUCTURE AND SERVICE FACILITIES, LOCATED WITHIN SAID EASEMENTS, DUE TO GRADE CHANGES OR GROUND
ELEVATION ALTERATIONS SHALL BE CHARGED TO THE PERSON OR PERSONS DEEMED RESPONSIBLE FOR SAID GRADE
CHANGES OR GROUND ELEVATION ALTERATIONS.
3. THIS PLAT DOES NOT AMEND, ALTER, RELEASE OR OTHERWISE AFFECT ANY EXISTING ELECTRIC, GAS, WATER, SEWER,
DRAINAGE, TELEPHONE, CABLE TV EASEMENTS OR ANY OTHER EASEMENTS FOR UTILITIES UNLESS THE CHANGES TO SUCH
EASEMENTS ARE DESCRIBED HEREON:
FOR SINGLE FAMILY RESIDENTIAL INCLUDE THE FOLLOWING:
4. CONCRETE DRIVEWAY APPROACHES ARE ALLOWED WITHIN THE FIVE (5) AND TEN (10) FOOT WIDE ELECTRIC AND GAS
EASEMENTS WHEN LOTS ARE SERVED ONLY BY UNDERGROUND ELECTRIC AND GAS FACILITIES.
5. ROOF OVERHANGS ARE ALLOWED WITHIN THE FIVE (5) AND TEN (10) FOOT WIDE ELECTRIC AND GAS EASEMENTS
WHEN ONLY UNDERGROUND ELECTRIC AND GAS FACILITIES ARE PROPOSED OR EXISTING WITHIN THOSE FIVE (5) AND TEN
(10) FOOT WIDE EASEMENTS.
STATE OF TEXAS
COUNTY OF BEXAR
I, , COUNTY CLERK OF BEXAR COUNTY, DO HEREBY
CERTIFY THAT THIS PLAT WAS FILED FOR RECORD IN MY OFFICE, ON THE DAY
OF
, A.D. 20 AT M. AND DULY RECORDED THE
DAY OF , A.D. 20 AT M. IN THE
OFFICIAL PUBLIC RECORDS OF BEXAR COUNTY, TEXAS, IN BOOK/ VOLUME
ON PAGE IN TESTIMONY WHEREOF, WITNESS MY HAND AND OFFICIAL SEAL
OF OFFICE, THIS DAY OF , A.D. 20 .
COUNTY CLERK, BEXAR COUNTY, TEXAS
BY:
, DEPUTY
SHOW ETJ LINE (IF APPLICABLE)
Bexar County Clerk's Recordation Template Block
is no longer needed as per their new system
generated recordation labels.
This area needs to have a minimum of 4 inches
in length and 2 1/2 inches high of blank space to
accommodate the new recording labels.
USE SIGNATURE BLOCK REQUIREMENTS
BELOW IF PLAT IS WITHIN BEXAR COUNTY:
LETTERING = 10 POINT FONT
DATE SPACING MINIMUM = 3/8” HIGH
SIGNATURE SPACING MINIMUM = 1/2” HIGH
MINIMUM SIGNATURE LINE LENGTH = 3”
MINIMUM DAY LENGTH = 1/2”
MINIMUM MONTH LENGTH = 1 1/2”
MINIMUM YEAR LENGTH = 1/3”